How to Use a Radon Detector

How to Use a Radon Detector - Air Testing Concept - Jarvis Nuclear

Why Should I Measure for Radon?

Radon is a naturally occurring radioactive gas that can build up indoors and is a significant cause of lung cancer, with long-term exposure increasing the risk.

As a result, measuring for radon is especially important in areas where radon gas levels are particularly high, such as Cornwall.

By measuring radon levels in homes and workplaces with a passive Long Term or Short Term Radon Detector Kit, you can identify potentially high concentrations so that appropriate action can be taken to protect the health of occupants and employees.

To help you get started with radon testing, at Jarvis Nuclear we decided to put together an in-depth guide on how to use a radon detector.

How to Use a Radon Detector - Step-by-Step Guide Concept - Jarvis Nuclear

How to Use a Passive Radon Detector: Step-by-Step Instructions

Using a radon detector is fairly straightforward. However, it’s important to position it correctly and leave it undisturbed for the recommended measurement period.

Whether you are measuring radon levels in your home or workplace, following the correct procedure will help ensure the results are reliable.

Please Note: Even though most passive radon detectors operate in a similar manner, you should always refer to the manufacturer’s instructions.

How to Use a Radon Detector - Short Term Detector - Jarvis Nuclear

Step 1: Unpack the Radon Detector

Each radon detector comes in a transparent, airtight bag to protect it before use.

Open the bag and remove the detector just before you are ready to position it. Once the airtight packaging has been removed, the detector begins measuring radon immediately. Make sure you have chosen a suitable location before opening the packaging.

Step 2: Choose the Correct Location

The correct location depends on whether you are measuring radon in a workplace or a home.

For Long Term Measurements

Long term measurements are the preferred method for both workplaces and homes. You need to position the detector in a suitable area where people regularly spend time. Ideally, it should be placed at around breathing height, approximately 1 to 2 metres above the floor.

You can place the detector on a shelf, attach it to a noticeboard or hang it from its loop if convenient.

For Short Term Measurements

Short term measurements should only be used where an indication of likely radon concentration is required. You should normally use two detectors, placing one in each of the following rooms:

Main living area: The room used most frequently during the day.

Main bedroom: The bedroom used regularly.

Position the detectors at around breathing height rather than on the floor. You can hang them from a suitable fitting, such as a lamp, or place them on a flat surface, such as a table or cabinet.

Regardless of where you’re measuring, keep detectors at least 25cm away from walls and out of reach of young children and pets.

How to Use a Radon Detector - Long Term Detector - Jarvis Nuclear

Step 3: Avoid Unsuitable Locations

The position of the detector can affect the reliability of the results. Avoid placing detectors in the following locations:

  • Direct sunlight: Choose a shaded position away from direct sunlight.
  • Draughts: Keep detectors away from areas with noticeable air movement.
  • Near heat sources: Avoid radiators, fireplaces, windowsills, televisions, and other electrical equipment that generates heat.
  • Inside objects: Do not place detectors inside cupboards, containers, or other enclosed objects.
  • Areas exposed to water: Keep detectors away from direct contact with water.
  • Floors and inaccessible spaces: Do not place detectors on the floor. They should also be kept out of ceiling voids, pipes, drains, and ducts.

These precautions help ensure the detector measures radon in the air of the occupied space rather than in an unsuitable location.

Step 4: Record the Detector Details

Before leaving the detectors in place, record the information needed to identify each one and track its measurement period.

For every detector, record:

  • The detector serial number.
  • The room or location where it has been placed.
  • The date and time it was installed.

We also recommend that you take a photograph of each detector in position. This provides a useful reference if you need to confirm its original location later.

Keep these details safe so you can match each detector to the correct location when the measurement period ends.

How to Use a Radon Detector - Chemical Element - Jarvis Nuclear

Step 5: Leave the Detectors in Place

Once positioned, the detectors should remain undisturbed throughout the measurement period. Do not move them to another room or location, as this could affect the measurement.

For long-term measurements, the detectors must remain in place for a minimum of 90 days.

For short-term workplace measurements, the measurement period is typically 10 days.

The detectors are passive devices, meaning they do not have moving parts and do not require a power supply to measure radon. They collect information over time, allowing radon levels to be assessed for the relevant period.

Step 6: Retrieve the Detectors and Record the Details

When the measurement period is complete, retrieve each detector carefully.

Record the date and time of removal for every detector, along with its serial number and location. This information should be kept with the original placement details.

For home measurements, make sure you have recorded both the installation and removal dates and times for the detectors in the living area and main bedroom.

Follow the supplied instructions for returning the detectors for analysis. Avoid opening or dismantling the detector itself.

By following these steps, you can help ensure your radon detectors are correctly positioned and your measurements provide useful information about radon levels in your building.

How to Use a Radon Detector - Paul at His Desk - Jarvis Nuclear

Radon Measurements & Professional Radon Services in Cornwall, Devon, Somerset & Dorset from Jarvis Nuclear

At Jarvis Nuclear, we provide passive radon testing kits for Short and Long Term measurements in homes and workplaces across Cornwall, Devon, Somerset, and Dorset. Now that you are aware of how to use a radon detector, you’re in a good place to start. Detectors are analysed by an accredited laboratory, and we can advise on any further action needed.

We can recommend organisations that provide radon remediation and help businesses and educational establishments complete radiation (radon) risk assessments where levels exceed the workplace Action Level.

Our services also include Radiation Protection Advisor (RPA) appointments, radon awareness training, and tailored Radiation Protection Supervisor (RPS) courses.

To find out more about our radon testing services and kits, call 07587 167711 or complete our online contact form.